5.3 Other Fatal Alarms


Code

Warning Message

Solution

505

Internal error

Program error; please check G codes in the program.

532

Please do homing first

Return to home as instructed.

533

Tool signal detected in none tool area

When G37 touch the probe for the first time and Z axis has been pulled up, check if probe signal is continue working and if there are probe error.

534

Cannot detect tool signal

While executing G37, within set traves probe signal not detected.

538

Please first do Z axis homing

Get axis to home

539

Please first do Y axis homing

Same as 538.

540

Please first do X axis homing

Same as 538.

561

When G94 mode execute tapping, corresponding current spindle speed, feed speed too small

Changing rigid tapping program or machine parameter rigid tapping related setting.

562

None rotary axis

Change CNC program or within machine parameter choose rotary axis.

563

PLC motion axis clash

Change PLC axis motion definition.

564

This program can only via program editor execute

Only use program editor to execute the program.

565

Rotary axis is locked

Please first dissolve rotary axis' lock.

572

G31 surpass limit

According to G31 menu order.

575

EtherCAT packet lost

Check EtherCAT cable.

600

PLC warning

PLC send out, detail please see error message dialog box.

574

System abnormal warning

System error, please provide CNC program to INTEK Technology for reference, to find the error and conduct change.


Out of memory, Divide by zero error, Exception error

Same as 574.