3.2.5 MPG Signal Input Selection
MPG A, B signals have two input sources, one is CN5 of EASVU0 and the other is from EKU; MPG signal can change the direction to match the machine movement direction.
Signal |
Function |
Explain |
oSVO_wleku |
MPG A/B phase signal input source selection |
0: EASVU0, 1: EKU |
oSVO_wlinv |
Inverse MPG A/B input signal |
0: no inverse, 1: inverse |