3.1.6 mode1


This part is listing mode1 signal and its description.


Signal

Function

Explain

sts.mode1.mG00

NC in G00 or G01 or G02 or G03 or G33 or G31

00: G00

01: G01

02: G02

03: G03

04: G33

05: G31

sts.mode1.mG51

NC in G50 or G51

0: G50, 1: G51

sts.mode1.mG68

NC in G69 or G68

0: G69, 1: G68

sts.mode1.mM29

NC in rigid tapping

1: Y, 0: N

sts.mode1.mG7101

NC in G71.00 or G71.01 (Direction track)

0: G71.00

1: G71.01

sts.mode1.mMFAvailable

Manual not allows

1: Y, 0: N

sts.mode1.mM00

NC in M00 program hold

1: Y, 0: N

sts.mode1.mG37

NC in G37

1: Y, 0: N

sts.mode1.mPlcSubOn

NC in PLC sub program

1: Y, 0: N

sts.mode1.mEEPROM

No function


sts.mode1.mXSVON

X-axis servo on

1: Y, 0: N

sts.mode1.mYSVON

Y-axis servo on

1: Y, 0: N

sts.mode1.mZSVON

Z-axis servo on

1: Y, 0: N

sts.mode1.mASVON

A-axis servo on

1: Y, 0: N