4.11.4.1 M00: Program Stop


If the M00 command is used in the program, the program will stop executing and the spindle will stop turning and the coolant will turn off when the M00 command is executed. If you want to continue to execute the next block, just press the start button or F9 key, the spindle rotates, the coolant turns on, and the program following M00 continues to execute. M00 instructions are generally used as a single block.