3.13.11.1 Bypass PLC on Controller Startup
This function is design to improve the problems cause by a lack of consideration of clients while writing PLC, leading to the CNC controller having exception error and not able to enter the system, after opening and need to use USB Flash Memory Disk to open the machine through DOS to delete the PLC.
Control instruction is as following:
1. |
After CNC controller is open, after the image show INTEK logo, the bottom would see the Loading image, user should press F10 within 3 seconds. |
2. |
After pressing F10, below the image it will show to bypass PLC ? And during the same time a 4 second count down would appear. |
3. |
Within the 4 second count down press Y, the CNC controller will not load the PLC, but use the PLC within the system. |
After you enter the system, user can enter machine parameter menu, re-enter or fix the PLC.