6.16 HSHP for Mass Production
1. |
The speed ratio set 20 to 29 to activate this function. |
2. |
When function was started, the sts.mode2.mFastHSHPCat1 and sts.mode2.mFastHSHPCat2 all became 1. |
3. |
This function was designed for simple line and curve NC program. The ACC/DEC was controlled by feed; and Speed Ratio controls speed of curve which by small G01. Smaller Speed Ratio lets curve speed down, but better precision; larger Speed Ratio lets curve speed up, but lower precision. At start set Speed Ratio from 25 for testing, and increase or decrease for best setting. |
The setting value of the reduction ratio at high speed and high precision is compared with the PLC signal as follows:
HSHP |
First Type High Speed Mode |
Second Type High Speed Mode |
HSHP for Mass Production |
||
Speed Ratio |
30~100 |
0~9 |
10~19 |
20~29 |
|
PLC Signal |
sts.mode2.mFastHSHPCat1 |
0 |
1 |
0 |
1 |
sts.mode2.mFastHSHPCat2 |
0 |
0 |
1 |
1 |