8.2 Axial Motion Alarms
Code |
Warning Message |
Solution |
506 |
X axis positive side soft limit tripped |
The software limit set for the axis, please check the machine parameter's software limit setting to be correct or if the working program has surpassed soft limit. |
507 |
X axis negative side soft limit tripped |
Same as 506. |
508 |
Y axis positive side soft limit tripped |
Same as 506. |
509 |
Y axis negative side soft limit tripped |
Same as 506. |
510 |
Z axis positive side soft limit tripped |
Same as 506. |
511 |
Z axis negative side soft limit tripped |
Same as 506. |
512 |
A axis positive side soft limit tripped |
Same as 506. |
513 |
A axis negative side soft limit tripped |
Same as 506. |
547 |
B axis positive side soft limit tripped |
Same as 506. |
548 |
B axis negative side soft limit tripped |
Same as 506. |
549 |
C axis positive side soft limit tripped |
Same as 506. |
550 |
C axis negative side soft limit tripped |
Same as 506. |
523 |
X axis positive side limit tripped |
The axis has touched limited switch. Please check whether the work has surpassed the limit of the switch position. |
524 |
X axis negative side limit tripped |
Same as 523. |
525 |
Y axis positive side limit tripped |
Same as 523. |
526 |
Y axis negative side limit tripped |
Same as 523. |
527 |
Z axis positive side limit tripped |
Same as 523. |
528 |
Z axis negative side limit tripped |
Same as 523. |
529 |
A axis positive side limit tripped |
Same as 523. |
530 |
A axis negative side limit tripped |
Same as 523. |
555 |
B axis positive side limit tripped |
Same as 523. |
556 |
B axis negative side limit tripped |
Same as 523. |
557 |
C axis positive side limit tripped |
Same as 523. |
558 |
C axis negative side limit tripped |
Same as 523. |
542 |
X axis over travel limit, position is lost, Please do home after recover |
Act according to instruction. |
543 |
Y axis over travel limit, position is lost, Please do home after recover |
Same as 542. |
544 |
Z axis over travel limit, position is lost, Please do home after recover |
Same as 542. |
545 |
A axis over travel limit, position is lost, Please do home after recover |
Same as 542. |
559 |
B axis over travel limit, position is lost, Please do home after recover |
Same as 542. |
560 |
C axis over travel limit, position is lost, Please do home after recover |
Same as 542. |
566 |
X axis home process index over limit |
1. Please check the wiring and confirm the connection of the home process index signal. 2. Please adjust the home process index offset distance to shorten the index searching distance. The index searching distance 400 ~ 900μ is recommended. |
567 |
Y axis home process index over limit |
Same as 566. |
568 |
Z axis home process index over limit |
Same as 566. |
569 |
A axis home process index over limit |
Same as 566. |
570 |
B axis home process index over limit |
Same as 566. |
571 |
C axis home process index over limit |
Same as 566. |