8.3 Other Fatal Alarms
Code  | 
Warning Message  | 
Solution  | 
505  | 
Internal error  | 
Program error; please check G codes in the program.  | 
532  | 
Please do homing first  | 
Return to home as instructed.  | 
533  | 
Tool signal detected in none tool area  | 
When G37 touch the probe for the first time and Z axis has been pulled up, check if probe signal is continue working and if there are probe error.  | 
534  | 
Cannot detect tool signal  | 
Same as 533.  | 
538  | 
Please first do Z axis homing  | 
Get axis to home.  | 
539  | 
Please first do Y axis homing  | 
Same as 538.  | 
540  | 
Please first do X axis homing  | 
Same as 538.  | 
561  | 
When G94 mode execute tapping, corresponding current spindle speed, feed speed too small  | 
Changing rigid tapping program or machine parameter rigid tapping related setting.  | 
562  | 
None rotary axis  | 
Change CNC program or within machine parameter choose rotary axis.  | 
563  | 
PLC motion axis clash  | 
Change PLC axis motion definition.  | 
564  | 
This program can only via program editor execute  | 
Only use program editor to execute the program.  | 
565  | 
Rotary axis is locked  | 
Please first dissolve rotary axis' lock.  | 
572  | 
G31 surpass limit  | 
According to G31 menu order.  | 
575  | 
EtherCAT packet lost  | 
Check EtherCAT cable.  | 
600  | 
PLC warning  | 
PLC send out, detail please see error message dialog box.  | 
574  | 
System abnormal warning  | 
System error, please provide CNC program to INTEK Technology for reference, to find the error and conduct change.  | 
Out of memory, Divide by zero error, Exception error  | 
Same as 574.  |