1 Environment and Maintenance Precautions
- Working Environment
Surrounding Temperature |
Allowable Temperature: 0℃ ~45℃ (No freezing) Storing Temperature: -15℃ ~65℃ (No freezing) |
Surrounding Humidity |
Allowable Humidity: Under 90% RH (No dewing) Storing Humidity: Under 90% RH (No dewing) |
Mist and Vapor |
Placed indoors, avoid direct sunlight. Stay away from oil mist and dust. Avoid corrosive and incendive gases. |
Elevation |
Under 1000m elevation |
Vibration |
Under 5 m/s2 |
- Maintenance Precautions
1. |
If the use of the environment power system instability, you must install regulators so that the power rate of change will not exceed 10% margin. |
2. |
It is recommended to keep the room temperature below 40℃ to keep the control system in a better working condition. |
3. |
According to the situation, clean the control box's network weekly or monthly to keep the control box well ventilated and cooled. |
4. |
When cleaning, use cotton cloth dip alcohol or scouring oil to wipe the panel and the button, do not use toluene or banana oil and other solvents to wipe. |
5. |
Avoid allowing cutting oil and iron chips to contaminate the control system's circuit board to prevent rapid aging of electronic components or short circuits in electronic circuits. |
6. |
Recommended reboot at least 20 seconds later, so as not to damage the controller. |