1 Environment and Maintenance Precautions


  • Working Environment

Surrounding Temperature

Allowable Temperature: 0℃ ~45℃ (No freezing)

Storing Temperature: -15℃ ~65℃ (No freezing)

Surrounding Humidity

Allowable Humidity: Under 90% RH (No dewing)

Storing Humidity: Under 90% RH (No dewing)

Mist and Vapor

Placed indoors, avoid direct sunlight.

Stay away from oil mist and dust.

Avoid corrosive and incendive gases.

Elevation

Under 1000m elevation

Vibration

Under 5 m/s2


  • Maintenance Precautions

1.

If the use of the environment power system instability, you must install regulators so that the power rate of change will not exceed 10% margin.

2.

It is recommended to keep the room temperature below 40℃ to keep the control system in a better working condition.

3.

According to the situation, clean the control box's network weekly or monthly to keep the control box well ventilated and cooled.

4.

When cleaning, use cotton cloth dip alcohol or scouring oil to wipe the panel and the button, do not use toluene or banana oil and other solvents to wipe.

5.

Avoid allowing cutting oil and iron chips to contaminate the control system's circuit board to prevent rapid aging of electronic components or short circuits in electronic circuits.

6.

Recommended reboot at least 20 seconds later, so as not to damage the controller.