3.12.1.8 Cancel 2nd servo check


If this option is checked, when the axial Max Lag Error exceeds the set value of the axial parameter, the controller will send an alarm message and servo off the servo drive.


If this item is not checked, the quick response servo check can be used to speed up the reaction time of the axial encoder feedback abnormality and quickly servo off the servo drive. The default value of this parameter is unchecked, and the default is to use the quick response servo check.